检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海理工大学动力学院制冷技术研究所,上海200093
出 处:《制冷学报》2006年第3期5-9,共5页Journal of Refrigeration
摘 要:以目前广泛使用的R22为工质,对Turbo-BⅡ管管内外换热性能进行了实验研究;管内以水为加热介质;在恒定热流密度与饱和压力不变条件下,改变进水水温和流速得到一系列实验数据,再通过威尔逊(Wilson)图解法同时得到管内外换热关联式;给出了不同管内流速时管外沸腾换热性能对比图;Turbo-BⅡ管管外沸腾换热性能比普通低翅管提高了1.6-2.5倍;在实验条件范围内,Turbo—BⅡ管内热阻是控制热阻。Pool boiling and internal heat transfer coefficients are experimentally analyzed of a kind of enhanced tube(Turbo- B Ⅱ ) with the refrigerant R22 used widely. The heating medium is water in tube. Maintain heat flux and saturation pressure constant, while vary inlet water temperature and velocity, then a series of data are obtained, inner and outer heat transfer coefficient correlations can simultaneously be figured out with Wilson Plot method. The heat transfer coefficient of enhanced tube is 1.6 - 2.5 times larger than that of low - fin tube. Within experimental condition, the inner thermal resistance dominates.
关 键 词:热工学 换热系数 Wilson图解法 强化传热 池沸腾
分 类 号:TB64[一般工业技术—制冷工程] TK172[动力工程及工程热物理—热能工程]