特高压直流平波电抗器的选择  被引量:10

Selection of ultra-high voltage direct current smoothing reactors

在线阅读下载全文

作  者:张劲松[1] 

机构地区:[1]广东省电力设计研究院,广州510600

出  处:《广东电力》2006年第5期36-38,45,共4页Guangdong Electric Power

摘  要:云广特高压直流输电工程缺乏实际的设备制造和运行经验,因此,应对设备的研究开发和选择给予特别重视。平波电抗器可选用干式空心或者油浸铁心式,应综合各种因素进行选择。提出云广特高压直流输电工程中平波电抗器的选择意见,并分析了研究开发特高压直流平波电抗器中应注意的事项。Yun-Guang ultra-high voltage direct current (UHVDC) transmission project lacks practical experience in equipment manufacture and operation. As a result, special attention should be paid to the research, development and selection of the equipments. As far as the smoothing reactor is concerned, dry. hollow type or oil-immersed iron-core type can be selected in consideration of various factors. In this paper, suggestions are put forth about choosing smoothing reactors for Yun-Guang UHVDC transmission project. Points for attention in developing UHVDC smoothing reactors are analyzed as well.

关 键 词:特高压直流 平波电抗器 比较 选择 研究开发 

分 类 号:TM478[电气工程—电器]

 