上安电厂高加损坏的对策及收益  

Countermeasure to Damage Problem of High-Pressure Heater of Shang'an Power Plant and Its Beneficial Resulut

在线阅读下载全文

作  者:宫学敏[1] 王统彬[2] 刘庆伏[3] 

机构地区:[1]华北电力大学电力设计院,保定071003 [2]保定电力职业技术学院,保定071000 [3]华能上安电厂,石家庄050000

出  处:《汽轮机技术》2006年第3期224-226,229,共4页Turbine Technology

摘  要:分析发电厂高加投入率低的原因,结合上安电厂350MW机组6号高压加热器损坏现象,提出6号高加汽侧退出运行时,应采取措施保证7号、8号高加的运行,并均衡其热负荷,以免个别高加过度超负荷。定义加热器回热率的概念,结合等效焓降法,计算高加切除对机组热经济性的影响。Analyze the reasons that high-pressure heates phase - in rate is always low, combining with damage appearance of #6 high -pressure heater(HP) of 350MW unit in Shang'an power plant, advance that measures should be taken to make No. 7 ,No. 8 HPs runningand balance thermal load of other HPs so as certain HP' s load not to be too high. Define the concept of heater regeneration rate, combine with equivalent enthalpy reduction method, calculated the influenee on heat economy of HPs being off - the line.

关 键 词:高压加热器 等效焓降法 热经济性 

分 类 号:TK264.9[动力工程及工程热物理—动力机械及工程]

 