血管内超声指导急性冠状动脉综合征患者药物洗脱支架置入的研究  被引量:1

Application of intravascular ultrasound in drug-eluting stent implantation in patients with acute coronary syndrome

在线阅读下载全文

作  者:陈玉国[1] 张运[2] 徐峰[1] 张梅[2] 李继福[2] 李贵双[2] 陈文强[2] 丁士芳[2] 吕瑞娟[1] 孙祎[1] 

机构地区:[1]山东大学心血管病研究中心山东大学齐鲁医院急诊科,济南250012 [2]山东大学心血管病研究中心山东大学齐鲁医院心内科,济南250012

出  处:《中华超声影像学杂志》2006年第6期401-404,共4页Chinese Journal of Ultrasonography

基  金:卫生部临床学科重点项目(20012943);山东省自然科学基金(2002BB1CJA1)

摘  要:目的探讨血管内超声(IVUS)指导药物洗脱支架置入的价值。方法对38例急性冠状动脉综合征患者67处病变行IVUS检查,指导药物洗脱支架置入。置入后再行IVUS,对未达到理想释放者进行高压球囊后扩张。观察6个月主要不良心脏事件。结果首次常规高压扩张置入支架,67处病变均达到冠状动脉造影理想标准,但符合IVUS理想标准仅40处(59.7%),27处(40.3%)未达标;行高压球囊后扩张,又有21处达到IVUS理想标准。最终达到IVUS理想标准者与常规高压扩张后比较,差异有统计学意义(91.0%对59.7%,P<0.0001)。随访期间无一例心源性死亡或再梗死,再发心绞痛2例(5.3%)。结论常规高压球囊扩张置入药物洗脱支架,并不能使所有支架达到IVUS理想标准。IVUS指导下高压球囊后扩张可进一步改善药物洗脱支架置入效果,具有重要临床价值。Objective To investigate the significance of intravascular ultrasound (IVUS) in drug-eluting stent implantation in patients with acute coronary syndrome (ACS). Methods IVUS was applied to evaluate 67 lesions of 63 coronary arteries in 38 patients and drug-eluting stent deployment. If IVUS criteria of optimal stent deployment were not met, post-dilatation with noncompliant balloons at higher pressure and reassessment with IVUS were performed. Major adverse cardiac events (cardiac death, reinfarction, recurrent angina and revascularization) during follow-up of six months were observed. Results Optimal angiographic criteria were achieved in all lesions after stenting with conventional high-pressure dilatation, but optimal criteria of IVUS were only obtained in forty lesions (59.7 %). Twenty-seven lesions (40.3 %) failed to achieve optimal criteria of IVUS and were treated with post-dilatation with 16 to 20 atm, then twenty-one lesions obtained the optimal criteria of IVUS. The frequency of achieving optimal criteria of IVUS increased from 59.7% to 91.0% (P 〈 0.0001). There were two patients of recurrent angina(5.3%), and no death and reinfarction were observed during follow-up. Conclusions All drug-eluting stent deployment under moderately high-pressure inflation could not achieve optimal criteria of IVUS. And post-dilatation with IVUS guidance could improve effects of intervention. Stenting with IVUS guidance is safe and effective.

关 键 词:腔内超声检查 血管成形术 经腔 经皮冠状动脉 支架 冠状动脉疾病 

分 类 号:R541.4[医药卫生—心血管疾病]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象