^(99)Tc^m-MIBI与^(13)N-NH_3心肌灌注显像评价兔亚急性心肌梗死缺血灶的准确性比较  

Comparison of accuracy between 99Tcm-MIBI and 13N-NH3 myocardial perfusion imaging in assessment of ischemic focus of rabbits with subacute myocardial infarction

在线阅读下载全文

作  者:周谊[1] 曾凡本 姚刚[1] 袁宝进[1] 周玲 刘兴旺[1] 乔宏庆[4] 

机构地区:[1]解放军第十一医院内二科,新疆维吾尔自治区伊犁市835000 [2]解放军兰州军区第二十九分部卫生处,新疆维吾尔自治区沙湾县832000 [3]新疆伊宁县东麻扎医院内科,新疆维吾尔自治区伊宁县835000 [4]解放军第四军医大学西京医院核医学科,陕西省西安市710033

出  处:《中国临床康复》2006年第24期124-125,i0001,共3页Chinese Journal of Clinical Rehabilitation

摘  要:目的:比较99Tcm-MIBI单光子计算机断层显像(SPECT)与13N-NH3正电子断层显像(PET/CT)两种心肌灌注显像方法,对兔亚急性心肌梗死灶显像的准确性。方法:实验于2003-10/2004-03在解放军第四军医大学西京医院核医学科3实验室进行。取8只雄性新西兰大白兔,结扎其冠状动脉左前降支,45min后松解形成再灌注。饲养7d后,再次结扎45min松解。2h后分别行99Tcm-MIBISPECT与13N-NH3PET/CT两种心肌灌注显像,通过定量化数据转化,计算心肌梗死灶缺损百分率,与TTC组织染色得出心肌梗死灶缺损百分率相比较。结果:8只兔全部进入结果分析。心肌梗死灶TTC染色后显示缺损度为(24.2±1.9)%,13N-NH3PET/CT显像显示缺损度为(23.7±2.3)%,两者均显著高于99Tcm-MIBISPECT心肌灌注显像(20.5±2.5)%,P<0.05。结论:13N-NH3PET/CT心肌灌注显像能更准确反映心肌梗死灶的实际范围。AIM: To compare the accuracy of myocardial perfusion imaging between ^99Tc^m-MIBI single photon emission computerized tomograph (SPECT) and ^13N- NH3 positron emission tomography/computerized tomography (PET/CT)in rabbits with subacute myocardial infarction. METHODS: The experiment was conducted at the Laboratory of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University of Chinese PLA between October 2003 and March 2004. Eight male New Zealand White rabbits of which left anterior descending (LAD) of coronary arteries were completely occluded for 45 minutes followed by reperfusion. One week later, the rabbits were ligated again for 45 minutes. Two hours later, myocardial perfusion imagings were performed on ^99Tc^m-MIBI SPECT and ^13N-NH3 PET/CT, respectively. Defect percentage of myocardial infarction heart was calculated by quantitative data transformation, and compared with the defect percentage of myocardial infarction heart determined by triphenyl tetrazolium chloride (TTC) staining. RESULTS: Totally 8 rats were involved in the result analysis. Infarct size were (24.2±1.9)% by TIC staining, while (23.7.±22.3)% by ^13N-NH3 PET/CT, and the both were significantly higher [(20.5±2.5)%,(P 〈 0.05)] by ^99Tc^m-MIBI SPECT. CONCLUSION: The ^13N-NH3 PET/CT myocardial perfusion imaging can more accurately reflect the infarct size.

关 键 词:心肌梗塞 心肌再灌注 体层摄影术 发射型计算机 单光子 正电子发射断层显像术 

分 类 号:R542.2[医药卫生—心血管疾病]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象