组合预氧化强化生物炭滤池处理微污染原水  被引量:7

Enhanced Biofiltration by Combined Preoxidation for Micropolluted Raw Water Treatment

在线阅读下载全文

作  者:秦庆东[1] 马军[1] 查人光[2] 沈莉萍[2] 王春[2] 朱海涛[2] 

机构地区:[1]哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090 [2]嘉兴市嘉源给排水有限公司,浙江嘉兴314000

出  处:《中国给水排水》2006年第13期26-29,33,共5页China Water & Wastewater

基  金:国家"十五"科技攻关课题(2002BA806B04)

摘  要:针对原水污染严重的实际情况,开展了以臭氧、高锰酸钾和粉末活性炭的组合预氧化工艺强化生物活性炭滤池去除嗅味、CODMn、氨氮等的生产性试验。当原水的CODMn和氨氮浓度分别为7.0、3.0 mg/L时,出水浓度分别为3.0、0.5 mg/L,且出水无嗅味。同时试验结果还表明,对CODMn的去除主要发生在预氧化过程中,生物活性炭滤池主要靠生物吸附和活性炭吸附去除CODMn。As raw water is terribly polluted, a full-scale experiment was carried out: The removals of odor, CODMn, and ammonia nitrogen were enhanced by the process of combined preoxidation in biofiltration, which contains ozone, potassium permanganate and powdered activated carbon (PAC). When the concentrations of the CODMn and ammonia nitrogen in raw water are 7.0 mg/L and 3.0 mg/L respectively, their concentrations in treated water are 3.0 mg/L and 0.5 mg/L, respectively. At the same time, the results also show that CODMn is removed mainly in the progress of preoxidation, while the removal of CODMn in biofihration depends on the adsorption of biological activated carbon.

关 键 词:微污染原水 组合预氧化 臭氧 高锰酸钾 粉末活性炭 生物活性炭滤池 

分 类 号:TU991.24[建筑科学—市政工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象