萃取分离基体-电感耦合等离子体质谱法测定高纯二氧化锆中痕量稀土杂质  被引量:10

Determination of trace rare earth impurities in high purity zirconium dioxide by inductively coupled plasma mass spectrometry after separation by solvent extraction

在线阅读下载全文

作  者:陈世忠[1] 

机构地区:[1]武汉工业学院重点实验室,湖北武汉430023

出  处:《冶金分析》2006年第3期7-10,共4页Metallurgical Analysis

基  金:湖北省自然科学基金资助项目(2005ABA025)

摘  要:建立了1-苯基-3-甲基-4-苯甲酰基-吡唑酮[5](PMBP)萃取分离基体-电感耦合等离子质谱法(ICP-MS)测定高纯二氧化锆中痕量稀土杂质的方法。结果表明,在2mol/L HNO3介质中,基体锆的萃取率为99.7%,而待测稀土元素则完全留在水相中。考察了影响萃取和测定的主要因素。在优化实验条件下,方法的测定下限为1.8~5.7ng/g,回收率在89.0%~110%之间,相对标准偏差(RSD)小于14%。A method was developed for the determination of trace rare earth impurities in high purity zirconium dioxide by inductively coupled plasma mass spectrometry(ICP-MS) after separation by solvent extraction. 1-phenyl-3-methyl-4-benzoyl-5-pyrazone(PMBP) was used as extractant. In 2 mol/L HNO3 medium,it was found that more than 99.7% of the Zr matrix was removed.The main factors affecting the extraction and determination,including acidity,PMBP amount and matrix concentration were investigated in detail. In the optimal conditions, the determination limits are 1.8-5.7 ng/g in solid ZrO2 with the relative standard deviations less than 14 % and recoveries of 89.0%-110 % for 14 rare earth impurities.

关 键 词:电感耦合等离子体质谱法 高纯二氧化锆 1-苯基-3-甲基-4-苯甲酰基-吡唑酮[5] 稀土杂质 溶剂萃取 