检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李元齐[1] 沈祖炎[1] 王磊[1] 王彦敏 徐宏伟[3]
机构地区:[1]同济大学,上海200092 [2]博思格建筑系统,上海201613 [3]宝山钢铁股份有限公司,上海201900
出 处:《建筑结构学报》2006年第3期18-25,共8页Journal of Building Structures
摘 要:本文收集了目前国内外屈服强度550MPa高强钢材冷弯薄壁型钢结构轴心受压构件的试验数据,参考现行的《冷弯薄壁型钢结构技术规范》(GB 50018—2002),对其承载力的合理计算模式进行了系统研究。结果表明,现行规范考虑板组约束计算截面有效宽厚比的方法对屈服强度550MPa高强钢材冷弯薄壁型钢结构轴心受压构件极限承载力的计算是可靠的。In this paper, in order to find a suitable method for load-carrying capacity analysis of 550MPa high-strength coldformed thin-walled steel colmnns subjected to axial compression with 550MPa, the related experimental data have been collected and compared with the theoretical results based on the effective width-to-thickness ratio method provided by "Technical code of cold-formed thin-walled steel structures" (GB 50018--2002). The results show that, the effective widthto-thickness ratio method, considering coupling stability of plates recommended in the technical code, can be reliably used to estimate the load-carrying capacities of the axially-compressed members of the high-strength cold-formed thin-walled steel structures.
关 键 词:高强冷弯薄壁型钢结构 轴心受压构件 承载力计算模式 板组约束 有效宽厚比