改进的合肥光源逐束团流强测量方案  被引量:2

Improvement of bunch-by-bunch beam current detection system in Hefei light source

在线阅读下载全文

作  者:郑凯[1] 王筠华[1] 刘祖平[1] 李为民[1] 周泽然[1] 杨永良[1] 黄龙君[1] 陈园博[1] 

机构地区:[1]中国科学技术大学国家同步辐射实验室,合肥230029

出  处:《强激光与粒子束》2006年第7期1178-1182,共5页High Power Laser and Particle Beams

基  金:国家自然科学基金资助课题(10175063)

摘  要:对于多束团运行的储存环,逐束团流强的测量是研究注入填充和束流不稳定性阈值等的重要内容。介绍了加速器常用的一些逐束团监测手段,在此基础上,利用HLS(Hefei Light Source)现有的逐束团测量设备,并配合相应前端信号处理电路,进行了HLS储存环逐束团流强测量。实验线路方面,在传统的高频频率倍频信号检波的基础上,尝试了新的与同步方波信号检波的方法。分别在多束团和单束团情况下对HLS的束团流强进行了连续检测实验,对实验结果进行线性拟合,得到了定标结果,结果表明系统的1阶线性拟合标准偏差均在1%左右;最后对其中非线性部分的物理本质进行了解释。Bunch-by-bunch beam current detection system is an important facility in the multibunch storage ring. In this paper, the established bunch-by-bunch beam current detection systems for the accelerator such as Cornell, SLAC and KEKB were compared and studied. The design of the bunch-by-bunch beam current detection system for HLS, which was based on the bunch-by-bunch tracing measurement system in HLS was given. Both demodulation by sine wave and square were applied in this paper, the deviation of the detect system was determined by the longitudinal oscillation. Compared the data acquired form ADC with the data from DCCT, the ADC data was scaled by the bunch current. The standard deviations of linear fit were about 1%, and the standard deviations of polynomial fit were less than 0.5 % in both sine wave and square wave demodulation. Some analysis of the measurement results also had been shown in this paper.

关 键 词:逐束团测量系统 束流流强 束团流强 方波检波 

分 类 号:TL506[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象