检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:徐征 张福俊 赵谡玲 王丽伟 A. N. Georgobiani V. B. Gutan 孟立建
机构地区:[1]Institute of Optoelectronics, Key Laboratory of Luminescence and Optical Information, Ministry of Education, Beijing Jiaotong University, Beijing 100044, China [2]Departamento de Fisica, Instituto Superior de Engenharia do Porto, 4200-072 Porto, Portugal [3]P. N. Lebedev Physical Institute of Russian Academy of Sciences, 117924, Moscow, Russia
出 处:《Chinese Physics B》2006年第8期1883-1887,共5页中国物理B(英文版)
基 金:Project supported by the National Natural Science Foundation of China (Grant Nos 10374001, 10434030 and 60576016), the State Key Development Program for Basic Research of China (Grant No 2003CB314707), the Excellent Doctor's Science and Technology Innovation Foundation of Beijing Jiaotong University (Grant No 48011), Russian Foundation of Basic Research (Grant Nos 04-02- 16942 and 02-02-39007).
摘 要:Thermo-luminescence (TL) is a kind of luminescence decay measured with varying temperature. In the process of TL the decay parameter itself involves the temperature effect of traps. Thus the trap depth is inseparable from the decay parameter. There are two separate peaks in the TL curve of ZnS:Cu,Co if the measurement starts from liquid nitrogen temperature. In the experiment we started from zero Celsius temperature to isolate the deeper traps. We have proposed and realized three methods for simultaneous determination of trap depth and decay parameter based on the quasi-equilibrium model and experimental data. If we treat the case of kinetic order a = 1 as a = 2, the error might be as large as 100%.Thermo-luminescence (TL) is a kind of luminescence decay measured with varying temperature. In the process of TL the decay parameter itself involves the temperature effect of traps. Thus the trap depth is inseparable from the decay parameter. There are two separate peaks in the TL curve of ZnS:Cu,Co if the measurement starts from liquid nitrogen temperature. In the experiment we started from zero Celsius temperature to isolate the deeper traps. We have proposed and realized three methods for simultaneous determination of trap depth and decay parameter based on the quasi-equilibrium model and experimental data. If we treat the case of kinetic order a = 1 as a = 2, the error might be as large as 100%.
关 键 词:THERMO-LUMINESCENCE trap depth monomolecular and bimolecular processes
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222