检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]青岛大学环境科学与工程系,山东青岛266071 [2]青岛普仁仪器有限公司,山东青岛266100
出 处:《岩矿测试》2006年第3期288-290,共3页Rock and Mineral Analysis
基 金:青岛大学研究生基金资助项目(061065)
摘 要:采用阴离子交换色谱电导检测法分析高纯镁砂(MgO)中的无机阴离子。MgO粉末在管式电炉1250-1350℃高温下通氧气加热,硫酸盐和氯化物等受热分解,气态生成物被40mL含25mg镁粉的0.25mol/LNaOH溶液吸收。方法的回收率为93.7%-95.3%,精密度(RSD,n=5)为4.32%-4.63%。对若干相关的分析技术问题,亦进行了讨论。A method for the determination of inorganic anions in high-pttfity MgO powder samples by ion exchange chromatography equipped with conductivity detector was presented. The sample mixture was heated in pipe electric furnace at the temperature of 1250 - 1350℃. Sulphate and chloride were decomposed and the gas products were adsorbed by 40 mL 0.25 mol/L NaOH containing 25 mg Mg powder. Recoveries of the method were 93.7% - 95.3% with precision of 4.32% - 4.63% RSD (n = 5). Some problems in the analysis were also discussed.