检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国海洋大学化学化工学院,山东青岛266003 [2]青岛海洋腐蚀研究所,山东青岛266071
出 处:《工业水处理》2006年第8期66-69,共4页Industrial Water Treatment
摘 要:用DPD(N,N-二乙基-1,4-苯二胺)比色法测定电解海水中的有效氯质量浓度,并将测定结果与碘量滴定法测定有效氯质量浓度相比较。此外,用该法在海水环境条件下,进行了试验。结果表明,在海水环境条件下,DPD比色法在常温下测定,选择波长为550 nm,溶液pH 6.5左右,显色后10 min内测定。用此方法测定海水中有效氯质量浓度的范围为0~2 mg/L,误差在5%以下。DPD (N,N-diethyl-1, 4-phenylenediamine) spectrophotometric method is used to determine the effective chlorine density of electrolyzed seawater. The results of DPD method is compared with the results of iodic titration, which determines the same sample. The conditions of the experiment are also studied in seawater. As a result, in seawater, effective chlorine density can be determined accurately in 0- 2 mg/L and the error is less than 5%. The optimum wavelength is 550 nm, the pH is about 6.5. The sample is determined in 10 min after reaction in normal temperature.
正在载入数据...