PMS-500可吸入颗粒物采样器的研制和性能测试  被引量:2

DEVELOPMENT OF AND PERFORMANCE FOR PMS-500 PM_(10) SAMPLER

在线阅读下载全文

作  者:刘龙波[1] 王旭辉[1] 刘蜀疆[1] 刘红杰[2] 吴艳敏[1] 常印忠[1] 殷宝辉[2] 翟涛[2] 夏兵[1] 张自禄[1] 

机构地区:[1]西北核技术研究所,西安710024 [2]中国环境科学研究院,北京100012

出  处:《辐射防护》2006年第5期257-263,共7页Radiation Protection

摘  要:研制了用于环境中可吸入颗粒物(PM10)采样的PMS-500采样器。采样器运行流量为560 m3/h,采用变频技术控制流量稳定,用聚丙烯纤维滤材作为PM10的收集介质。设计了一种矩形喷嘴撞击器作为PM10切割器,撞击器的收集介质为容尘量较大的聚氨酯泡沫。对采样器的性能测试结果为:切割器的切割粒径为9.9μm,捕集效率曲线的几何标准偏差为1.4;采样期间流量波动在±2%之内;双层滤材对0.2μm气溶胶的收集效率不小于99%。采样器可方便地拆分为三部分,机动性较好。本采样器与市售大流量PM10采样器的采样效率相当,其性能可以满足环保行业对PM10采样的要求。PMS-500 PM10 sampler for monitoring the radionuclides in PM10 was developed and evaluated. The flowrate of the sampler was 560 m^3/h. A variable frequency technique was used to control the flowrate. An impactor with rectangle jets was designed as PM10 inlet, and polypropylene foam was used as collection substrate. Fibrous filters were selected as filtration media for PM10. The sampler can be easily detached into three parts so its portability was improved. The performance of the sampler was valuated, and the results showed that the cut-off diameter of the PM10 inlet was 9.9 tma with a GSD of 1.4. The flowrate was stable in ±2% while sampling. The collection efficiency of the filter for 0.2 pan aerosol was not lower than 99%. The collection efficiency of the sampler is equiralent to that of a commercial high volume PM10 sampler. It is demonstrated that the PMS-500 PM10 meets common requirements of a PM10 sampler.

关 键 词:PM10 气溶胶 采样器 研制 

分 类 号:X851[环境科学与工程—环境工程]

 