摘 要:电压型开关在配网自动化中有广阔的发展前景,但也具有开关动作时间过多等缺点。通过分析U-T曲线,结合实际运行,本文提出了一种缩短非故障线路恢复供电的方法,可以更好的为用户服务。By right of its advantages the usage of voltage-controlled switches has a bright development future in power distribution network automatization. However in which there are still some disadvantages, such as switching operation is so much, and the time delay is so long. According to the analysis on U-T curves and combining actual operation, a way to shorten the power broken time of non-fault lines is presented. By this way, FA system controlled by voltage could serve the users better.
分 类 号:TM732[电气工程—电力系统及自动化]