高效生物滴滤塔处理硫化氢臭气的试验研究  被引量:8

Study on treatment of hydrogen sulfide odor by high efficiency bio-trickling filter

在线阅读下载全文

作  者:杨基先[1] 李天罡 

机构地区:[1]哈尔滨工业大学市政环境工程学院,哈尔滨150090 [2]天津北方伊世特工程技术有限公司,天津300201

出  处:《哈尔滨工业大学学报》2006年第8期1333-1335,共3页Journal of Harbin Institute of Technology

摘  要:针对生物脱臭处理工艺存在的问题,在实验室用化学方法产生H2S气体,利用筛选、驯化的高效除臭菌形成的固定化生物滤料进行连续脱臭试验.结果表明:当H2S进气量在0.05~0.5m^3/h,进气质量浓度在300~700mg/m^3时,反应器对H2S的去除率均在98%以上.反应器运行时pH值的下降并不影响H2S的去除效果.反应器启动快并能够保证足够的反应时间,具有较高的除臭效率.The removal experiment of odor containing hydrogen sulfide ( H2S) in lab was carried out continuously in high - efficient biological deodorization reactor packed with ceramics on which screened and cultivated bacterium were immobilized. Removal efficiency can reach above 98% under following conditions: the concentration of inlet between 300 mg/m^3and 700 mg/m^3 , the gas flow between 0.05 m^3/h and 0.5m^3/h. The decrease of pH did not affect the removing efficiency of hydrogen sulfide. The retention time of the reactor is long enough to treat odor efficiently.

关 键 词:恶臭 硫化氢 生物滴滤塔 

分 类 号:X701[环境科学与工程—环境工程]

 