检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]哈尔滨锅炉厂有限责任公司,黑龙江哈尔滨150046
出 处:《黑龙江电力》2006年第4期266-268,共3页Heilongjiang Electric Power
摘 要:为了研究金属材料探伤仪器缺陷定位的准确度,阐述了斜探头前沿长度b值的3种测定方法。通过分析和判定,认为多点法测量的准确度高于二点法,一点法的测定误差最大。In order to study the accuracy for defectometer to locatc the defects, three kinds of methods of taeasuring front distance, that is b value, of angle sensor were discussed. It is believed that the accuracy obtained by multi - points measuring method is higher than that of two - points method, in addition, the accuracy of one - point method is the lowest.
分 类 号:TG115.28[金属学及工艺—物理冶金]