痕量氟的Al^(3+)-Calcein配合物荧光熄灭测定法  

DETERMINATION OF TRACE FLUORIDE WITH Al ̄(3+)-CALCEIN COMPLEX BY FLUORO-QUENCHING METHOD

在线阅读下载全文

作  者:李华斌[1,2,3] 姚延伸 张继伦[1,2,3] 张洪仪 谭舒敏 

机构地区:[1]华西医科大学公共卫生学院 [2]四川师范大学化学系 [3]四川师范大学分析测试中心

出  处:《四川师范大学学报(自然科学版)》1996年第6期96-99,共4页Journal of Sichuan Normal University(Natural Science)

摘  要:本文建立了痕量氟的Al3+-Calcein配合物荧光熄灭测定法.该法激发波长480um,发射波长503um,线性范围2~150μg/F-,灵敏度为2μg/LF-,100μg/LF-时标准偏差为1.3μg/LF-,是现有的最灵敏方法之一.用茜素络合剂分光光度法进行对照实验,二者获得的结果一致.A fluoro-quenching method for the determination of fluoride within Al3+-Calcein complex is established. The excitation and emission wavelengths are 480um and 503nm, respectively. Rectilinear ranges is 2-150μg/L F-. The sensitivity of the method i3 2μg/L F- and the standard deviation of determination is 1. 3μg/L F -for 100μg/L of fluoride. The obtained results agree with those by spectrophotometry with alizarin complex. Theaccuracy and precision of the present method is satisfactory.

关 键 词: 测定  配合物 荧光熄灭法 CALCEIN 

分 类 号:O613.41[理学—无机化学] O657.3[理学—化学]

 