电网电压波动对中板四辊轧机主传动系统的影响及对策  

Influence on electric grid voltage fluctuation on main drive system for four-high medium plate mill and its countermeasure

在线阅读下载全文

作  者:王军 

机构地区:[1]南京钢铁股份有限公司中板厂,江苏南京210035

出  处:《冶金自动化》2006年第5期60-62,共3页Metallurgical Industry Automation

摘  要:介绍了电网电压波动对中板四辊轧机主电机传动系统的影响和解决方法。根据中板四辊轧机主电机传动系统运行时的上级监控系统记录数据,以及直流电机电枢电压与变流器交流侧输入电压的关系,详尽地分析了直流快速自动开关跳闸故障原因,并提出具体的对策及措施。Influence of electric grid voltage fluctuation on main motor drive system for four-high medium plate mill and its solution are introduced. According to recording data of higher level monitor and control system when main motor drive system for four-high medium plate mill is operated, and relation between armature voltage of DC electromotor and AC input voltage of inverter, trip cause of DC fast automatic switch was analyzed in detail, and specific countermeasure and measures are given.

关 键 词:电网波动 中板四辊轧机 主电机传动系统 变流器 

分 类 号:TM711[电气工程—电力系统及自动化] TM921

 