平行热线法测定松散煤体导热系数试验  被引量:12

Experiment of Parallel Hot Wire Technique for Measuring Thermal Conductivity in Loose Coal Bulk

在线阅读下载全文

作  者:唐明云[1] 张国枢[1] 张朝举 束永保[3] 邱进伟[1] 

机构地区:[1]安徽理工大学资源开发与管理工程系,安徽淮南232001 [2]皖北煤电公司祁东矿,安徽宿州234000 [3]国家安全生产监督管理总局信息研究院,北京100029

出  处:《矿业安全与环保》2006年第5期13-15,共3页Mining Safety & Environmental Protection

基  金:安徽省自然科学基金资助项目(050450404)

摘  要:根据国际标准的平行热线法原理,设计出测定松散煤体导热系数试验装置,给出了其计算方法,并对祁东煤矿的不同粒径及不同含水量的煤质进行了反复试验,结果表明:随着粒径及含水量的增加,煤体导热系数呈上升趋势,且越趋平稳;最后对结果作了详细分析。An experimental device for the measurement of the thermal conductivity of loose coal bulk was designed based on the internationally standardized Hot Wire Method (parallel) theory, its calculation method was derived and repeated tests were carried out on the coal with different particle size and humidity in Qidong Coal Mine. The test results showed that the thermal conductivity is tending to increase and becomes stable with the increase of particle size and water content of coal. Finally, analysis was made on the test results.

关 键 词:平行热线法 松散煤体 导热系数 粒度 含水量 

分 类 号:TD752.2[矿业工程—矿井通风与安全] O482.22[理学—固体物理]

 