摘  要:CFB(循环流化床)锅炉是新一代高效、低污染清洁型燃烧锅炉,在国内得到广泛应用。但CFB锅炉发电机组自动控制系统尤其是协调控制系统设计不成熟,投运一直是个难题。在分析河北省保定热电厂原协调控制策略的基础上提出了改进措施:完善了一次调频功能;设计了汽机侧的“压力偏差回拉功率”回路,以限制汽机侧调门的动作速率;将直接能量平衡策略改为间接能量平衡策略;为克服锅炉燃料调节的滞后性使用了燃料前馈。最后对改进后系统的调节性能进行了评价。Based on the analysis of the original CCS of Baoding Cogeneration Power Plant, some improvements are presented. The frequency regulation has been modified; The "press deviation dragging load" loop has been designed in order to limit the response speed of turbine valve; The direct Energy Balance (DEB) strategy has been replaced by Indirect Energy Balance (IEB) strategy; Fuel feedforward has been used to compensate the time delay of the CFB boiler. The performance of the improved CCS is also evaluated.