低压电网抗谐波无功自动补偿装置的选择  被引量:1

Choice of reactive self-compensating equipment with harmonic wave resistance in low-voltage grid

在线阅读下载全文

作  者:王连符[1] 肖峻[2] 

机构地区:[1]唐山职业技术学院机械电子系,唐山064002 [2]天津大学电气工程及其自动化学院,天津300072

出  处:《机电设备》2006年第5期I0032-I0036,共5页Mechanical and Electrical Equipment

摘  要:谐波对电力系统的无功补偿装置将产生严重危害,为了确保低压无功自动补偿装置稳定、可靠地工作,文中应用非正弦电路无功功率的有关理论,对低压无功功率补偿装置的各种类型进行了比较,提出了配置低压无功自动补偿装置的步骤及其方法,最后给出一选择实例.该方法对低压电网无功补偿装置的升级改造具有重要的实际意义.Harmonic waves do serious harm to compensating devices for reactive power in electric power system. In order to ensure that self-compensating devices for reactive power work stably and reliably in low-voltage electric power system, this paper introduces a new method and steps of selecting compensating devices by comparing their types, based on the theory of reactive power in non-sinusoidal alternating circuit. Finally, an illustrative example is given to clarify the proposed method and to demonstrate its effectiveness in the aspect of upgrading reactive power compensating devices in low-voltage grid.

关 键 词:谐波 电力系统 无功补偿 低压电网 

分 类 号:TM714.3[电气工程—电力系统及自动化]

 