机构地区:[1]唐山职业技术学院机械电子系,唐山064002 [2]天津大学电气工程及其自动化学院,天津300072
出 处:《机电设备》2006年第5期I0032-I0036,共5页Mechanical and Electrical Equipment
摘 要:谐波对电力系统的无功补偿装置将产生严重危害,为了确保低压无功自动补偿装置稳定、可靠地工作,文中应用非正弦电路无功功率的有关理论,对低压无功功率补偿装置的各种类型进行了比较,提出了配置低压无功自动补偿装置的步骤及其方法,最后给出一选择实例.该方法对低压电网无功补偿装置的升级改造具有重要的实际意义.Harmonic waves do serious harm to compensating devices for reactive power in electric power system. In order to ensure that self-compensating devices for reactive power work stably and reliably in low-voltage electric power system, this paper introduces a new method and steps of selecting compensating devices by comparing their types, based on the theory of reactive power in non-sinusoidal alternating circuit. Finally, an illustrative example is given to clarify the proposed method and to demonstrate its effectiveness in the aspect of upgrading reactive power compensating devices in low-voltage grid.
分 类 号:TM714.3[电气工程—电力系统及自动化]