检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:高楼军[1] 柴红梅[1] 孙雪花[1] 郭延红[1]
出 处:《分析试验室》2006年第9期84-87,共4页Chinese Journal of Analysis Laboratory
基 金:延安大学科学基金项目(YD2004-116)
摘 要:将流动注射技术引入邻菲罗啉分光光度法测定Fe^2+分析体系,采用单阀双带镀镉锌片还原柱带隔离的阀体流路,建立了同时测定微量Fe^2+和Fe^3+的分析方法。Fe^2+的测定范围为0~10mg/L,检出限为1.2×10^-6mg/L;Fe^3+的测定范围为0~12mg/L,检出限为1.8×10^-6~mg/L。方法用于水中Fe^2+和Fe^3+的同时测定。A flow injection spectrophotometry is proposed for simultaneous determination of iron ion ( Ⅱ ) and iron ion (Ⅲ) based on o-phenanthroline spectrophotometry, using double zone injection and a reduction column packed with cadmium plated zinc power. The ranges of determination are 0 - 10 mg/L for Fe( Ⅱ ) and 0 - 12 mg/L for Fe( Ⅲ ). The limits of detection are 1.2 × 10^-6 mg/L for Fe( Ⅱ) and 1.8 × 10 ^-6 mg/L for Fe(Ⅲ ). This method has been applied to the determination of Fe( Ⅱ ) and Fe( Ⅲ ) in water with satisfactory results.