ICP-MS法同时测定食用级碳酸钙中Ba、AS、Pb、Hg、Cd、Cr  被引量:2

Determination of Ba、As、Pb、Hg、Cd、Cr in eatable calcium carbonate by ICP-US

在线阅读下载全文

作  者:刘永林[1] 周萍[1] 章新泉[1] 易永[1] 姜玉梅[1] 苏亚勤[1] 李翔[1] 

机构地区:[1]江西省分析测试研究所,南昌330029

出  处:《江西化工》2006年第3期60-62,共3页Jiangxi Chemical Industry

摘  要:本文采用电感耦合等离子体质谱仪(ICP-MS)直接测定食用级碳酸钙中Ba、As、Pb、Hg、Cd、Cr有害重金属元素的含量。用硝酸低温溶解碳酸钙样品,加入内标元素1n,采用内标法,有效地补偿了基体效应所带来的测量偏差。该方法的加标回收率为:95%-110%,测定精度(RSD)为:0.7%-4.3%。本文所研究的方法具有简便、快速、准确等特点,可用于食用级碳酸钙样品有害元素的分析。A method for the directly determination of harmful elements Ba, As, Pb, Hg, Cd, Cr in eatable calcium carbonate by ICP - MS ELAN - 9000 was reported in this paper. Samples were dissolved directly with HNO3 under a heat of one hundred degrees. The matrix and spectral interference during measuring had been studied. The matrix interference was corrected by adding internal standard elment as in. Otherwaise, the spectral interference was avoided by selection isotopes of elements. The recovery is 95% -110%, and RSD is 0. 7 % -4.3 %. The method has a characteristic of simply rapaid and accelerate. It can be applied to the determination of harmful elements in eating calcium carbonate.

关 键 词:ICP—MS 食用级碳酸钙 有害重金属元素 分析 

分 类 号:O657.63[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 