检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《华北电力技术》2006年第10期1-4,共4页North China Electric Power
基 金:国家自然科学基金项目(50077013)
摘 要:针对变压器冲击试验,提出了中性点电流法、传递函数法和联合时频分析法等3种故障诊断方法。结合具体实例,分别用3种不同的方法对电力变压器进行故障诊断,其中着重介绍了联合时频分析法。通过对3种方法的优缺点进行分析比较,认为联合时频分析法是最先进、准确性最高的方法,具有良好应用前景。Against transformers impulse tests, the paper presented neutral point current, function of transmission and joint time-frequency analysis methods for fault discrimination. Specific examples of, respectively, using three different methods of power transformers for fault discrimination, which highlights the joint time-frequency analysis. Through analysis of the advantages and disadvantages of three methods comparison, joint time-frequency analysis is considered to be the most advanced and highest accuracy of the method and has good prospects for applications.
分 类 号:TM83[电气工程—高电压与绝缘技术]
正在载入数据...