检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:万沐[1] 刘海男[1] 谷现良[2] 高甫生[2] 赵加宁[2]
机构地区:[1]沈阳铝镁设计研究院 [2]哈尔滨工业大学
出 处:《暖通空调》2006年第10期79-81,共3页Heating Ventilating & Air Conditioning
基 金:沈阳铝镁设计研究院与哈尔滨工业大学联合开发科研项目(沈铝院科合字(2003)第02号)
摘 要:通过模拟计算研究了架空层位于地面之上和地面之下这两种常见的2层结构铝电解厂房的自然通风效果。结果表明,架空层位于地面之下时,地面阻挡对进风口风量有很大影响,当凹槽宽度为1 m时,总风量约减少45%;宽度为3 m时,影响较小,风量约减少9%;宽度为3.5 m时,阻挡的影响可忽略。Studies by simulation the natural ventilation effect in typical two-storied aluminum electrolytic plants with the operation floor above and under the ground level. As a result, the ground has a significant block effect on the air volume through the bottom inlet. When the distance between the soil wall and outer wall of plant is about 1 metre, the total air volume can be reduced by about 45%, and when the distance is 3 metres, the air volume reduction is much smaller and about 9%, and when the distance is enlarged to 3.5 metres, the influence can be neglected.
分 类 号:TU834[建筑科学—供热、供燃气、通风及空调工程]