摘 要:目的评价CT仿真支气管内窥镜的临床应用价值。方法32例患者均有纤维支气管镜对照并经病理、手术证实。使用计算机软件将图像数据重建为三维支气管立体图像,通过鼠标操作进入支气管腔内检查。结果CT仿真支气管内窥镜检查25例中心型肺癌,结核病4例,炎症1例,正常2例。结论CT仿真支气管内窥镜是一种无创性安全的检查方法,可部分取代纤维支气管镜。Objective To evaluate clinical applications of CT virtual bronchoscopy. Methods 32 patients were examined with CT bronchoscopy. All were proved with fiberoptic bronchoscopy and pathology operation. The crosssectional images were reconstructed to 3 Dtracheobrochial image using computer software and navigate of "fly ghrough" from trachea to subsegmental bronchus simulating fiberoptic bronchoscopy. Results CT virtual bronchoscopy could reveal 25 patients with cancer of lung. Other findings tuberculosis,inflammation,and normal. Conclusion CT virtual bronchoscopy providesan noninvasive and safe examination method,with may partly replace fiberoptic bronchoscopy.