29MW低倍率循环流化床热水锅炉的设计  被引量:7

Design of a 29MW Low Circulation Ration Fluidized Bed Hot Water Boiler.

在线阅读下载全文

作  者:别如山[1] 杨励丹[1] 鲍亦令[1] 陆慧林[1] 吴文渊[1] 张子栋[1] 

机构地区:[1]哈尔滨工业大学

出  处:《动力工程》1996年第4期39-42,共4页Power Engineering

摘  要:阐述了低倍率循环流化床高温热水锅炉的设计要点:低倍率燃烧方式,中温分离,双级燃烧,密相区保留埋管,工质侧采用强制循环,水系统采用各受热面管内流动方向一律向上的强制循环方式。计算结果表明,大容量循环床高温热水炉在突然停电时比较安全。此外,提出了必要的停电保护措施。Abstract The following main design feature of a low circulation fluidized hot waterboiler are elucidated: combustion with low circulation ration, separation undermiddling temperature, two stage combustion, submerged tubes retained in thedense phase region and forced circulations of the working medium, so that the flowdirection within the tubes of the heating surface is exclusively upwards. Calculation shows that circulating bed hot water boilers are more safe, in case of powerdisruption. The paper also lists some protective measures against power disruption.

关 键 词:热水锅炉 低倍率 循环流化床 流化床锅炉 

分 类 号:TU833.11[建筑科学—供热、供燃气、通风及空调工程] TK229.66[动力工程及工程热物理—动力机械及工程]

 