检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]平顶山工学院建筑环境与热能工程系,河南平顶山467001
出 处:《热能动力工程》2006年第6期573-577,共5页Journal of Engineering for Thermal Energy and Power
摘 要:针对锅炉传统冷、热态性能试验存在的局限性,以220t/h四角切圆燃烧锅炉为原型,建立其可实现的k-ε数学模型,结合锅炉冷态性能试验,利用计算流体力学软件Fluent模拟炉内空气动力场。数值模拟结果与冷态试验结果的基本一致性和两种结果分布趋势的较好吻合性说明该数值模拟方法能较好地反映炉内真实的流场特性,验证了所建数学模型的正确性及可靠性,为进一步完善锅炉冷态性能试验和进行热态数值试验提供更全面的数据信息。With a 220 t/h tangentially corner-fired boiler serving as a prototype, a realizable k-ε mathematical model has been established to cope with the limitations of traditional cold and hot-state performance tests of boilers. In combination with cold-state performance tests of boilers, in-furnace aerodynamic fields were simulated by using software FLUENT of computational fluid dynamics. The basic agreement of the numerical simulation results with those of cold-state performance tests and comparatively good coincidence of the distribution tendency of both results indicate that the numerical simulation method under discussion can relatively well reflect the true characteristics of in-furnace flow fields. Hence, the foregoing has demonstrated the correctness and reliability of the mathematical model, providing more comprehensive data and information for further improving boiler cold-state performance tests and for performing hot-state numerical tests.
分 类 号:TK224[动力工程及工程热物理—动力机械及工程]