检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]莱芜钢铁集团有限公司自动化部,山东莱芜271104 [2]莱芜钢铁集团有限公司
出 处:《冶金自动化》2006年第6期60-62,共3页Metallurgical Industry Automation
摘 要:阐述了电弧炉冶炼时所产生的无功冲击、谐波电流、负序电流等对电网及电气设备的影响,并以莱钢特殊钢厂50 t超高功率电弧炉应用德国西门子SVC技术为例,阐述了SVC设置的原则,SVC主接线和SVC的控制原理等。SVC投入运行后,对非线性负荷产生的谐波电流,电压波动及闪变等引起供电电能质量的问题起到了很好的治理效果。Influence of idle power impact, harmonic current and negative sequence electric current on electrical network and electric equipment during arc furnace smelting are introduced. SVC technique of Siemens was applied to 50 t uhm high power arc furnace in Special Steel Plant of Laiwu Iron and Steel Group Co Ltd. Setting principle, main wiring and control principle of SVC are described. After SVC was put into operation, power quality problem caused by harmonic current, voltage fluctuation and flicker has been solved.
关 键 词:动态无功补偿装置 超高功率电弧炉 公共供电点 晶闸管控制电抗器 谐波
分 类 号:TM924.4[电气工程—电力电子与电力传动]
正在载入数据...