检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《热力发电》2006年第11期61-62,共2页Thermal Power Generation
摘 要:传统测量重油中的硫方法存在分析时间长、分析效率低、操作复杂、重复性差的缺点。应用X-射线荧光光谱仪测定重油中硫的含量,并将其结果与库仑滴定法测定结果相比较,偏差为0.004%,在GB/T 214-1996允许误差之内。试验表明,X-荧光法具有操作方便、速度快、重复性良好等优点。Traditional method used for determining sulfer content in heavy oil has some shortcomings,such as long analysing duration,low analysing efficiency,complex operation,and bad repeatability etc..Using X-ray fluoresence spectrometer to determine sulfer content in heavy oil,and comparing the measured results with that of Coulomb's tittrimetric method,the deviation to be only 0.004%.it is within the allowable error stipulated in National Standard GB/T 214-1996.The test shows that the X-ray fluoresence method has advantages as convenient operation,fast speed,and good repeatabilibity etc..
分 类 号:TK16[动力工程及工程热物理—热能工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30