作  者:胡志军[1] 李友明[1] 陈元彩[1] 雷利荣[1] 袁号[1] 郭滂[1] 黎章飞[1] 

机构地区:[1]华南理工大学造纸与污染控制国家工程研究中心,广州510640

出  处:《造纸科学与技术》2006年第6期120-123,共4页Paper Science & Technology

基  金:广州市科技局企业难题招标项目(GK040311));学生研究计划-复合三维电极脱色技术资助。

摘  要:采用电生成Fenton法预处理CTMP废水,主要考察了pH、电流密度、反应时间和温度对废水色度和CODC r去除率的影响,并初步探讨了电芬顿试剂的作用机理。通过实验得到最佳反应条件:极板间距10 cm、曝气、pH=5、电流密度80A/m2和反应时间60m in,最佳条件下脱色率达90%以上,CODC r去除率50%以上。The clectro-Fenton process technology was used in treating CTMP wastewater. The main influencing factors,e, g. pH, reaction time, temperature and current density, were investigated and the decoloring mechanism of electro-Fenton process was preliminary discussed. The results showed that at the optimum conditions with pH values of 5.0, 80A/m^2 of current density, and reaction time of 60min and aeriation, its color removal rate was above 90% and COD removal rate was above 50%.

关 键 词:电FENTON法 脱色 CTMP废液 