检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]南京工程学院动力系,南京210013 [2]扬州大学水利科学与工程学院,江苏扬州225009
出 处:《水力发电学报》2006年第6期145-148,共4页Journal of Hydroelectric Engineering
基 金:江苏高校省级重点实验室开放课题(KJS03087)
摘 要:火电厂冷却水泵进水池通常采用矩形进水池,通过分析表明矩形进水池的流态并非十分理想,水力设计尚需改进。因此提出蜗形进水池方案代替矩形进水池,并且通过模型试验来研究两类进水池水力性能的优劣。试验中采用美国进水设计标准中旋度计测量涡角检验进水性能的方法。试验结果表明蜗形进水池优于矩形进水池。研究结论和传统的泵装置性能试验结论一致,表明通过涡角检验进水性能的方法是可靠正确的。The rectangle intake sumps are usually used for the intake of thermal power plant. However, the flow pattern of which is not good, its design needs to be improved. The volute intake sump is substituted for the rectangle intake sump. The hydraulic performance test between the volute intake sump and the rectangle intake sump are conducted by model experiment. Vortex angles are measured by the swirlmeter and are used for checking the hydraulic performance of intake sump. Model experiment results indicate that the volute intake sump is better than the rectangle intake sump and the method of experimental investigation with vortex angle is reliable and correct.
分 类 号:TV131.2[水利工程—水力学及河流动力学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©