发电偏离电量的网损影响  

Generating Electricity Deviation and Its Influence on Incremental Power Loss

在线阅读下载全文

作  者:陈宇晨[1] 曹敏年[1] 翟海青[2] 赵岩[2] 侯昀[2] 

机构地区:[1]上海工程技术大学电气工程系,上海201620 [2]上海市电力公司,上海200122

出  处:《上海大学学报(自然科学版)》2006年第6期557-561,共5页Journal of Shanghai University:Natural Science Edition

基  金:上海市教委科技发展基金资助项目(02FK02);上海市科委科技成果证书登记号(9312005Y0998)

摘  要:运用发电偏离电量与网损分配的数学模型,通过特定电网对电量偏离的特征和影响进行了计算与分析.由于电源点离负荷中心的电气距离不同,形成了两种典型的发电偏离电量网损微增特性.按照发电偏离电量对电网运行的影响,提出了3种偏离程度的认定与划分判据.此方案已被电力部门采纳,经实际运行,证明是切实可行的.This paper presents a model for analyzing and calculating the incremental electric power loss under the situation of generating deviation occurring in one or several grid nodes. Aimed at a designated grid, two kinds of incremental power loss curves are studied. Taking into consideration multi-load level, we carry out three types of generating deviation standards and describe their characteristics. The described method has been used in practice and proved to be feasible.

关 键 词:电力市场 电网 发电偏离电量 网损微增 网损分配因子 

分 类 号:TM71[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象