不同构造形式轻钢龙骨复合墙体湿传递分析  被引量:6

Analysis on moisture transfer for two light steel-framed composite walls

在线阅读下载全文

作  者:王昭俊[1,2] 崔永旗[3] 张素梅[1] 

机构地区:[1]哈尔滨工业大学土木工程博士后科研流动站 [2]黑龙江省建工集团有限责任公司博士后科研工作站,哈尔滨150001 [3]哈尔滨工业大学市政环境工程学院

出  处:《哈尔滨工业大学学报》2006年第11期1819-1822,共4页Journal of Harbin Institute of Technology

基  金:中国博士后科学基金资助项目(2005038528);哈尔滨市墙体材料改革建筑节能科研项目(2005-3)

摘  要:根据蒸汽渗透理论对两种不同构造形式的腹板开孔轻钢龙骨复合墙体进行了传湿分析.结果表明:远离龙骨处的保温层冷侧更易结露,且该处的保温层采暖期重量湿度增量值较龙骨附近的大.墙体2的构造形式比墙体1的构造形式防潮效果好,墙体1须设防潮层才能满足墙体保温与防潮等热工性能要求.Based on the theory of moisture permeation, moisture transfer of the slotted light steel - framed composite wall is analyzed. The results show that the condensation of moisture is easily occurred in the insulation layer far away from the steel - framed component and its moisture accumulation is also more than that of other places. From the point of moisture-proof view,wall 2 with polystyrene board is better than that of wall 1 with rock wool. The layer of moisture-proof must be placed in wall 1 to meet thermal performances of wall.

关 键 词:传湿 结露 湿增量 防潮层 轻钢龙骨复合墙体 

分 类 号:TU111.19[建筑科学—建筑理论]

 