Measurements of AIM for Visible Wavelength Based on Individual Eye Model  被引量:4

Measurements of AIM for Visible Wavelength Based on Individual Eye Model

在线阅读下载全文

作  者:王伟 王肇圻 王雁 左彤 赵堪兴 

机构地区:[1]Institute of Modern Optics, Nankai University, Tianjin 300071 [2]Refractive Surgery Center, Tianjin Eye Hospital, Tianfin 300020

出  处:《Chinese Physics Letters》2006年第12期3263-3266,共4页中国物理快报(英文版)

基  金:Supported by the Key Project of the National Natural Science Foundation of China under Grant No 60438030, the Key Research Foundation of Scientific and Technical Committee of Tianjin City of China under Grant No 033183711, and the Specialized Research Fund for the Doctoral Programme of Higher Education of China under Grant No 20050055002.

摘  要:We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer function (MTF) of human eye in visible wavelengths. Using CSV-1000 and VAF-1000, the contrast sensitivity function (CSF) and the visual acuity (VA) for the same eye are measured. Then the AIM of human retina could be acquired by the relations between MTF and CSF and between MTF and VA. The AIM of human retina is independent of MTF, and the values of AIM for normal eyes (without retina disease) are similar, so the assembly average for large numbers of normal eyes can be a standard AIM curve, which is helpful for the diagnosis of diseases in the retina system.We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer function (MTF) of human eye in visible wavelengths. Using CSV-1000 and VAF-1000, the contrast sensitivity function (CSF) and the visual acuity (VA) for the same eye are measured. Then the AIM of human retina could be acquired by the relations between MTF and CSF and between MTF and VA. The AIM of human retina is independent of MTF, and the values of AIM for normal eyes (without retina disease) are similar, so the assembly average for large numbers of normal eyes can be a standard AIM curve, which is helpful for the diagnosis of diseases in the retina system.

关 键 词:WAVE-FRONT ABERRATIONS 

分 类 号:O431[机械工程—光学工程] R770.424[理学—光学]

 