A Newly Developed Non-Destructive Tritium Measurement Technique and Its Application to V-4Cr-4Ti Alloy  

A Newly Developed Non-Destructive Tritium Measurement Technique and Its Application to V-4Cr-4Ti Alloy

在线阅读下载全文

作  者:刘翔 陈学 H.HOMMA Y.HATANO M.MATSUYAMA 

机构地区:[1]Southwestern Institute of Physics,Chengdu 610041,China [2]Sichuan General Fire Brigade,Chengdu 610072,China [3]Hydrogen Isotope Research Centre,Toyama University,Gofuku 3190,Toyama 930-8555,Japan

出  处:《Plasma Science and Technology》2006年第6期741-744,共4页等离子体科学和技术(英文版)

基  金:supported by the China-Japan Core University Program(Task1-2A)

摘  要:A non-destructive and in-situ technique for the measurement of tritium in materials, namely β-ray-induced X-ray spectrometry (BIXS), has been developed recently. In the present study a V-4Cr-4Ti alloy was pre-heated at 1000℃ for 2 h to form a recrystallization structure before the tritium absorption experiments were conducted. Firstly the hydrogen isotope gas was charazterized by means of a quadrupole mass spectrometer (QMS) and a small-sized ionization chamber. Then hydrogen isotope absorption tests of V-4Cr-4Ti alloy were performed at 400 ℃ and the atomic concentration of hydrogen isotope in V-4Cr-4Ti alloy was estimated as 0.17% with a tritium content of approximately 2.5 ppm. Experimental results indicate that BIXS is a quite useful tool for quantitatively measuring the tritium content and tritium distribution in the surface layers of vanadium alloys and no strong trapping effects of tritium exist in the pre-heated V-4Cr-4Ti alloy.A non-destructive and in-situ technique for the measurement of tritium in materials, namely β-ray-induced X-ray spectrometry (BIXS), has been developed recently. In the present study a V-4Cr-4Ti alloy was pre-heated at 1000℃ for 2 h to form a recrystallization structure before the tritium absorption experiments were conducted. Firstly the hydrogen isotope gas was charazterized by means of a quadrupole mass spectrometer (QMS) and a small-sized ionization chamber. Then hydrogen isotope absorption tests of V-4Cr-4Ti alloy were performed at 400 ℃ and the atomic concentration of hydrogen isotope in V-4Cr-4Ti alloy was estimated as 0.17% with a tritium content of approximately 2.5 ppm. Experimental results indicate that BIXS is a quite useful tool for quantitatively measuring the tritium content and tritium distribution in the surface layers of vanadium alloys and no strong trapping effects of tritium exist in the pre-heated V-4Cr-4Ti alloy.

关 键 词:tritium V-4Cr-4Ti β-ray-induced X-ray spectrometry tritium measurements 

分 类 号:O536[理学—等离子体物理]

 