一体化A/O生物膜反应器低温硝化研究  被引量:7

Study on Nitrification in a Combined Biofilm Reactor at Low Temperature

在线阅读下载全文

作  者:张秀红[1] 周集体[1] 郭海燕[2] 纪磊[1] 曲媛媛[1] 

机构地区:[1]大连理工大学环境与生命学院,大连116023 [2]大连交通大学环境科学与工程学院,大连116028

出  处:《环境科学》2007年第1期142-146,共5页Environmental Science

摘  要:采用自行设计制作的新型一体化A/O生物膜反应器,研究了温度、进水碱度对反应器硝化性能的影响.结果表明,当反应器温度控制在20,15和10℃时,硝化率分别为98%,90%和60%.此时进水COD和TN浓度分别为100—150mg/L和65—78mg/L.总氮去除率分别为50%,30%和20%.当反应器温度控制在8℃,进水中不加有机碳源,随着进水碱度的增加,硝化率从72%提高到95%,在低温下取得了良好的硝化效果.当进水碱度为280mg/L时,反应器各区出现亚硝酸盐积累,亚硝化率达到80%.详细分析了形成亚硝酸盐积累的原因.An experimental study was carried out to investigate the nitrification performance of a novel combined airlift biofihn reactor devised and made by our lab. The results showed that when the temperature of the reactor was maintained at 20,15 and 10℃ ,the nitrification efficiency was 98% ,90% and 60% respectively with the influent COD ranging between 100 - 150 mg/L and TN being 65 - 78 mg/L. Under the above conditions the total nitrogen removal efficiency was 50% ,30% and 20% as a result of the absence of organic carbon and low temperature. At 8℃ ,nitrification efficiency increased (from 72% to 95% ) in evidence with the increasing influent alkalinity when no organic carbon was added to the influent. When the influent alkalinity was 280 mg/L,nitrite accumulation occurred in each zone of the reactor. The accumulation rate was as high as 80% . The reason of nitrite accumulation was analysed in detail.

关 键 词:一体化生物膜反应器 硝化 短程硝化 温度 碱度 

分 类 号:X703.1[环境科学与工程—环境工程]

 