检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]山东工业大学测试中心
出 处:《分析测试技术与仪器》1996年第4期38-41,共4页Analysis and Testing Technology and Instruments
摘 要:利用计算机控制和数据处理技术对进口核磁共振谱仪加以改造,使其测试所要求的环境温度由原来的恒温(20±1℃)降至室温。其精度保持不变,硬件方案简捷可靠、软件利用一个标准样品的已知参数来校正系统的刻度单位,算法采用动态的可调刻度单位标定其它样品的测试结果,取得了较为理想的效果。An imported NMR spectrometer is modified by applying computer control and data-processing technique. The operational temperature is changed from 20±1℃ to room temperature while its precision keeps unchanged. The hardware scheme is simple and reliable. Using known parameters of a standard sample, the software corrects the graduation unit of the system. Dynamic adjustable graduation unit is adopted for the algorithm. Known parametres of a standard sample are approached through double-identification and multi-repetition. The test results of other samples by using corrected graduation unit are satisfactory. Factors and regularities affecting the precision of the NMR spectrometer are also discussed.