检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]天津大学电气与自动化工程学院,天津市300072
出 处:《电力系统自动化》2007年第2期36-40,共5页Automation of Electric Power Systems
基 金:国家自然科学基金资助项目(50477037)~~
摘 要:提出一种用于超高压和特高压输电线路上的分相方向元件。通过比较故障分量补偿电压和故障前电压的相位,从而判断是否正方向故障。该分相方向元件具有极强的方向性,能反应系统全相、非全相和振荡状态下的各种对称和不对称故障,具有很高的承受过渡电阻的能力。通过各种情况下大量仿真试验证明了此原理的优越性。A segregated phase directional relay is proposed, which can be used on EHV and UHV transmission lines. Faults in the protected and reverse directions can be reliably identified by comparing the phase angles of the fault component compensated voltage and voltage prior to fault. With its remarkable directional identifying capability, the relay proposed can maintain reliable operation even under fault in power swing and two-phase operation conditions and allows for great fault resistances. Its excellent properties have been proved by numerous digital simulations.
分 类 号:TM761[电气工程—电力系统及自动化]