地下柴油发电站机房的通风与降温设计  被引量:7

Ventilation and cooling design of underground diesel generator rooms

在线阅读下载全文

作  者:郭春信[1] 尧勇[1] 李刻铭[1] 

机构地区:[1]解放军理工大学

出  处:《暖通空调》2007年第2期71-75,37,共6页Heating Ventilating & Air Conditioning

摘  要:介绍了柴油发电机组的几种换热方式与发热量的构成。强调了采用通风降温时,换热器的热风不能排入机房,应直接排入排风道,再由耐高温风机排至室外。通过实例说明了这种降温方式最小进排风量的计算方法。介绍了目前工程中存在的几个共性问题,并提出了解决方法。Presents several heat exchanging modes of the diesel generator room and the composition of heat release. Emphasizes that hot air from heat exchanger should be taken into air chute, not into generator room, and then to be discharged outdoor by a high temperature resistant fan when the generator is cooled by ventilation. Presents the computational method of the minimum intake and exhaust air rate with an example, and puts forward some common existed problems in projects and their solutions.

关 键 词:柴油发电站机房 通风降温 风帽 换热器 

分 类 号:TU834.5[建筑科学—供热、供燃气、通风及空调工程]

 