Preliminary Design and Analysis of ITER In-Wall Shielding  

Preliminary Design and Analysis of ITER In-Wall Shielding

在线阅读下载全文

作  者:刘常乐 郁杰 武松涛 蔡影祥 潘皖江 

机构地区:[1]Institute of Plasma Physics,Chinese Academy of Sciences,Hefei 230031,China

出  处:《Plasma Science and Technology》2007年第1期94-100,共7页等离子体科学和技术(英文版)

基  金:the National 973 program of China(No.2004CB720704)

摘  要:ITER in-wall shielding (IIS) is situated between the doubled shells of the ITER Vacuum Vessel (IVV). Its main functions are applied in shielding neutron, gamma-ray and toroidal field ripple reduction. The structure of IIS has been modelled according to the IVV design criteria which has been updated by the ITER team (IT). Static analysis and thermal expansion analysis were performed for the structure. Thermal-hydraulic analysis verified the heat removal capability and resulting temperature, pressure, and velocity changes in the coolant flow. Consequently, our design work is possibly suitable as a reference for IT's updated or final design in its next step.ITER in-wall shielding (IIS) is situated between the doubled shells of the ITER Vacuum Vessel (IVV). Its main functions are applied in shielding neutron, gamma-ray and toroidal field ripple reduction. The structure of IIS has been modelled according to the IVV design criteria which has been updated by the ITER team (IT). Static analysis and thermal expansion analysis were performed for the structure. Thermal-hydraulic analysis verified the heat removal capability and resulting temperature, pressure, and velocity changes in the coolant flow. Consequently, our design work is possibly suitable as a reference for IT's updated or final design in its next step.

关 键 词:ITER VV in-wall shielding shielding blocks (SB) finite element (FE) structure analysis thermal/hydraulic analysis 

分 类 号:O532.1[理学—等离子体物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象