亚临界汽包锅炉氢氧化钠处理炉水质量控制研究  

Quality control for caustic treatment for subcritical drum units

在线阅读下载全文

作  者:朱莉[1] 王安宁[2] 

机构地区:[1]上海外高桥发电有限责任公司,上海200137 [2]华东电力试验研究院有限公司,上海200437

出  处:《华东电力》2007年第2期56-59,共4页East China Electric Power

摘  要:外高桥发电有限责任公司2号机组炉水采用氢氧化钠处理前期,炉水氢电导率和氯离子含量时有超标现象。分析了造成炉水氢电导率和炉水氯离子含量超标的主要原因,通过调整凝结水精处理运行方式,使炉水的氯离子稳定、可控,解决了磷酸盐处理工况时氯离子易出现的超标现象,防止了氯离子对炉管的腐蚀隐患,取得了良好的经济效益。In the early stage of caustic treatment for the No. 2 unit of Shanghai Waigaoqiao Power Generation Co. , Ltd. , the cation conductivity and the chloride content in the boiler water often exceed the standards. After analysis, the main reasons are found out, and by adjusting the condensate polishing methods, the chloride content in the boiler water became stable and controllable. The high chloride content occurred during phosphate treatment is solved, and the possibility of boiler tube corrosion by chlorine ions is eliminated.

关 键 词:锅炉 氢氧化钠处理 水汽品质 凝结水精处理 

分 类 号:TM621.8[电气工程—电力系统及自动化]

 