USING CAPILLARY WHOLE BLOOD GLUCOSE TEST IN SCREENING FOR GESTATIONAL DIABETES MELLITUS  

USING CAPILLARY WHOLE BLOOD GLUCOSE TEST IN SCREENING FOR GESTATIONAL DIABETES MELLITUS

在线阅读下载全文

作  者:吴氢凯 罗来敏 顾京红 李萍 黄亚绢 冯洁 张睿 

机构地区:[1]Department of Obstetrics and Gynecology, the Sixth People’s Hospital, Shanghai Jiaotong University

出  处:《Journal of Shanghai Second Medical University(Foreign Language Edition)》2007年第1期23-26,共4页上海第二医科大学学报(英文版)

基  金:Supported by grants from the Natrual Science Foundation of Shanghai, China (99ZB14071).

摘  要:To discuss whether the capillary whole blood glucose (CBG) test can be used in glucose screening test (GST) for gestational diabetes mellitus (GDM) compared to the venous plasma glucose ( VPG) method, and to determine the cutoff value of CBG. Methods This was a self-control test. The 50-g oral GST was conducted among 1 557 pregnant women between 24-28 weeks. Every woman was measured CBG and VPG at the same time and same arm. Three hundred and forty women underwent 100-g 3-h oral glucose tolerance test (OGTT). Receiver operation curve (ROC) was used to determine the potential cutoff level of CBG and VPG. Diagnose criteria of GDM was based on NDDG criteria. OGTT diagnosed GDM and VPG ≥ 7. 8 mmol/L were used as golden standard for ROC. Results There was good relationship between CBG and VPG ( P 〈0.01 ). Correlation coefficient was O. 86. The value of CBG was lower than VPG. The statistical and high-sensitivity cutoff values were 7. 4 mmol/L in CBG and 7. 8 mmol/L in VPG when GDM was used as golden standard. Cutoff value of CBG was 7. 0 mmol/L when VPG≥7. 8 mmol/L was used as golden standard. The pregnant outcomes of positive cases of three thresholds had no significant differences. But it was better in case of the pregnant woman when the CBG value was more than 7. 4 mmol/L. Conclusion CBG can be used in GST, the threshold of CBG was suggested as 7. 4 mmol/L. CBG test was more convenience and effective than VPG test.Objective To discuss whether the capillary whole blood glucose (CBG) test can be used in glucose screening test (GST) for gestational diabetes mellitus (GDM) compared to the venous plasma glucose (VPG) method, and to determine the cutoff value of CBG. Methods This was a self-control test. The 50-g oral GST was conducted among 1 557 pregnant women between 24-28 weeks. Every woman was measured CBG and VPG at the same time and same arm. Three hundred and forty women underwent 100-g 3-h oral glucose tolerance test (OGTT). Receiver operation curve (ROC) was used to determine the potential cutoff level of CBG and VPG. Diagnose criteria of GDM was based on NDDG criteria. OGTT diagnosed GDM and VPG≥7.8 mmol/L were used as golden standard for ROC. Results There was good relationship between CBG and VPG (P<0.01). Correlation coefficient was 0.86. The value of CBG was lower than VPG. The statistical and high-sensitivity cutoff values were 7.4 mmol/L in CBG and 7.8 mmol/L in VPG when GDM was used as golden standard. Cutoff value of CBG was 7.0 mmol/L when VPG≥7.8 mmol/L was used as golden standard. The pregnant outcomes of positive cases of three thresholds had no significant differences. But it was better in case of the pregnant woman when the CBG value was more than 7.4 mmol/L. Conclusion CBG can be used in GST, the threshold of CBG was suggested as 7.4 mmol/L. CBG test was more convenience and effective than VPG test.

关 键 词:gestational diabetes mellitus glucose screening test capillary whole blood glucose diagnostic criteria 

分 类 号:R587.2[医药卫生—内分泌]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象