检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]天津城建学院
出 处:《建筑热能通风空调》2007年第2期59-63,共5页Building Energy & Environment
摘 要:本文根据标准k-ε双方程紊流模型,采用有限容积法,利用Airpak商业软件包对辐流洁净室内气流场进行了CFD模拟。通过模拟计算和分析,对辐流洁净室内在高效过滤器的外面加装扇型散流孔板的必要性进行了研究,并得出高效过滤器设置在顶棚比设置在侧墙更合理。从空气龄的角度认为房间适宜的长高比在1.5~2之间。另外,通过研究还发现对传染性隔离病房辐流是一种比较合理的气流组织形式。According to k-ε double equation turbulent flow model, using limited volume method and Airpak commercial software package, the air distribution in vector-flow clean room is studied. Through the simulative calculation and analysis, the necessity of fixing sector diffusion orifice panel outside HEPA in the vector flow clean room are analyzed, and so it is more suitable that arranging the high efficiency particular air filter on the roof than on the side wall. According to velocity field and air ages, the right ratio of length to height in the room should be between 1.5-2. In addition, the result shows that vector flow is a relatively ideal flow pattern of air flow for contagious isolation wards.
分 类 号:TU834[建筑科学—供热、供燃气、通风及空调工程]