铝阳极电凝聚处理活性黑KN-B染料模拟废水  

Treatment of Reactive Black KN-B Simulated Wastewater by Electro-coagulation With a Sacrificial Al Anode

在线阅读下载全文

作  者:杨蕴哲[1] 胡筱敏[1] 梁吉艳[1] 

机构地区:[1]东北大学资源环境与土木工程学院

出  处:《工业安全与环保》2007年第5期13-16,共4页Industrial Safety and Environmental Protection

摘  要:对铝阳极电凝聚处理活性黑KN-B模拟废水进行了初步的实验研究。考察了电流密度、初始pH值、电解质浓度及种类、温度、染料浓度等因素的影响。结果表明,在一定实验条件下,活性黑KN-B模拟废水的脱色效率可达到88%;电流强度、染料浓度、电解液初始pH值、氯化钠电解质浓度、温度对染料溶液脱色效率的影响明显,而硫酸钠电解质浓度对脱色效率的影响不显著;在电凝聚处理过程中,主要作用机理是吸附网捕占主导地位;活性黑KN-B在阴极上发生了还原反应。Preliminary experimental study is conducted on the treatment of C.I.reactive black KN-B simulated wastewater by electro-coagulation with a sacrificial Al anode.Some factors are investigated,such as current density,initial pH,sorts,concentration of electrolyte and dye and temperature.The results show that the decoloration rate of the simulated wastewater can reach 88% and it is strongly affected by the strength of the current,initial pH,temperature,concentration of dye and NaCl,but lightly affected by the concentration of Ns2SO4; absorption and sweep is predominated in the electro-coagulation process and at the same time the reduction of dye on the cathode occurs.

关 键 词:铝阳极 电凝聚 活性染料 脱色 

分 类 号:X703[环境科学与工程—环境工程]

 