检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]北京市放射卫生防护所
出 处:《辐射防护》1997年第1期62-67,共6页Radiation Protection
摘 要:本文介绍对北京地区使用的工业X射线探伤机泄漏辐射情况进行调查的方法与结果。共抽查了北京、上海等地8个厂家生产的21台探伤机,其中北京、丹东和日本厂家生产的16台,均为气体冷却的便携式探伤机,上海和德国生产的5台,为水冷或油冷却探伤机。用FJ-347A型X、γ剂量仪对探伤机X射线管头距靶1m处的泄漏辐射空气比释动能率进行了测试。调查测试结果表明,依据我国机械工业部1985年发布的专业标准(ZBY315-85),5台水冷或油冷式探伤机的防护性能全部合格,而气冷式探伤机只有2台合格,其余14台探伤机X射线管头泄漏辐射水平超标,其超标的测点主要分布在管头的阴极侧。文中对探伤机泄漏辐射超标的原因进行了分析。This paper introduces investigation methods and results for radiation leakage from X ray flaw detectors, which are used in Beijing area. Total 21 sets of flaw detectors made in 8 factories in Beijing, Shanghai etc. have been tested, of which 16 sets made in Beijing, Dandang and Japan are gas cooling flaw detectors, and rest 5 sets made in Shanghai and Germany are water or oil cooling detectors. The air Kerma rate of leadage radiation at 1 m from the X ray tube targat were measured by Type FJ 347A X, γ dosimeter. It can be seen from the results that, compared with the trade standard ZBY315 85, 5 sets of water or oil cooling flaw detectors are all qualified. however, only two sets of gas cooling detectors are qualified, and the radiation leakage of another 14 sets are over the values specified in the standard. The reason is analyzed, and some advices about the measures of improving radiation protection structure design and production technology for the unqualified products have been proposed. (
分 类 号:TH878.1[机械工程—仪器科学与技术]