用GB6913.3-86测定阻垢缓蚀剂中总磷存在的问题与改进  

PROBLEMS EXISTING IN DETERMINATION OF THE TOTAL PHOSPHORUS IN ANTISCALE CORROSION INHIBITORS BY USING GB69 13.3-86 AND IMPROVEMENT THEREOF

在线阅读下载全文

作  者:樊坤[1] 黄善锋[1] 陈浩[1] 史庆琳[1] 田利[1] 罗奖合[1] 王广珠[1] 张建福 黄晓忠 

机构地区:[1]西安热工研究院有限公司,陕西西安710032 [2]华电红雁池发电有限责任公司,新疆乌鲁木齐830047 [3]蒲城发电有限责任公司,陕西蒲城715501

出  处:《热力发电》2007年第4期91-92,79,共3页Thermal Power Generation

摘  要:对GB6913.3-86《锅炉用水和冷却水分析方法磷酸盐的测定总磷酸盐》测定阻垢缓蚀剂中总磷酸盐误差大的问题进行研究,通过试验认为加热分解时间短是引起误差的主要原因,找出了消除误差的方法,从而拓展了该方法的适用范围。Directing against the problems of large error occurred in determination of total phosphorate (total phosphorus) in antiscale corrosion inhibitor by using National Standard GB 6913.3 -86 《Determination of phosphorate i. e. total phosphorate, in boiler water and cooling water by using analytical method》, a study has been carried out, and a method for eliminating the said error being found through test, thereby, extending the scope of application for the said method.

关 键 词:原水 锅炉水 冷却水 总磷酸盐测定 加热分解 阻垢缓蚀剂 

分 类 号:O655[理学—分析化学]

 