检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙江中材工程设计研究院有限公司,浙江杭州310000
出 处:《水泥工程》2007年第3期9-16,共8页Cement Engineering
摘 要:烧成系统废气处理的工艺设计优劣,直接影响除尘效果的好坏和能源效益的高低,因此合理的工艺计算和系统配置非常重要。文章详细地介绍了废气增湿塔的喷水量计算方法;探讨了立磨系统增湿塔的合理位置、风机的节能运行以及尾卸或中卸磨系统的工艺设计;同时对增湿塔系统的自控操作也进行了分析研究。Dedusting effect and energy efficiency of the firing system depends on the technical design of its waste gas processing system, and then reasonable technical calculation and system allocation is very important. The paper introduced in detail the calculating method of the water quantity sprayed into the waste gas conditioning tower, and discussed the reasonable position of the gas conditioning tower, saving energy running of the fan and technical design of the end and middle discharge mill system, at the same time, studied the autocontrol operation of the gas conditioning tower system.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.186