厌氧流化床处理红霉素废水的研究  被引量:4

Research of treating crythromycin wastewater in an anaerobic fluidized bed reactor

在线阅读下载全文

作  者:周健[1] 张会展[1] 方春玉[1] 

机构地区:[1]四川理工学院生物工程系,四川自贡643000

出  处:《工业水处理》2007年第6期54-57,共4页Industrial Water Treatment

摘  要:研究了中温(33~35℃)条件下,厌氧流化床(AFB)反应器处理红霉素废水的运行特性。结果发现:进水COD为6 900 mg/L、HRT为4.4 h时,COD、BOD的去除率分别达到了76.6%、65.9%。最后利用Garrett-Sawyer关系式求出了难生物降解的有机物浓度,并利用Monod模型对实验结果进行了动力学分析,得出了红霉素废水中温条件下厌氧消化过程的基质降解规律。Crythromycin wastewater is treated in an anaerobic fluidized bed reactor (AFB) with granular activated carbon as carrier,operating at 33-35℃. The operating characteristic is studied. The test result demonstrates that the removal efficiency of COD and BOD are 76.6% and 65.9% respectively as influent COD is 6 900 mg/L and HRT is 4.4 h. The non-biodegradation organism concentration is obtained by Garrett-Sawyer formula. And the degradation equation for the anaerobic digestion of crythromycin wastewater is concluded by employing the Monod model.

关 键 词:红霉素废水 废水处理 厌氧流化床 

分 类 号:X703.1[环境科学与工程—环境工程]

 