Thermogravimetric Studies of Deposited Potash Impregnated for Flame-Retardancy into a Cotton Fabric  

Thermogravimetric Studies of Deposited Potash Impregnated for Flame-Retardancy into a Cotton Fabric

在线阅读下载全文

作  者:MOSTASHARI, S.M. NIA, Y.K. BALE, S. 

机构地区:[1]Department of Chemistry, Faculty of Science, the University of Gilan, Rasht, lran

出  处:《Chinese Journal of Chemistry》2007年第7期926-929,共4页中国化学(英文版)

摘  要:The effect of potash as a nondurable finish on the flammability of 100% cotton fabric (plain 180 g/m^2) was investigated. The bone-drled weighed fabrics were dipped into suitable concentrations of potash, with a volume of 100 mL at 20-2℃. The impregnation was followed by means of squeeze rolls and drying at 110 ℃. The samples were then reweighed with analytical precision. After conditioning overnight by using our "vertical flame tester" the optimum add-on values to impart flame-retardancy to cotton fabric was determined and expressed by 0.80 g of potash per 100 g fabric to be an efficient addition. Thermogravimetric analysis of pure cotton, treated cotton with potash at its optimum efficiency for donation of flame-retardancy into cotton fabric was fulfilled and the thermograms were compared and commented. The effectiveness of this hydroxide was attributed to the heat dissipation by the remaining consumed material during the combustion. The results obtained are in favor of "Dust or Wall Effect Theory".The effect of potash as a nondurable finish on the flammability of 100% cotton fabric (plain 180 g/m^2) was investigated. The bone-drled weighed fabrics were dipped into suitable concentrations of potash, with a volume of 100 mL at 20-2℃. The impregnation was followed by means of squeeze rolls and drying at 110 ℃. The samples were then reweighed with analytical precision. After conditioning overnight by using our "vertical flame tester" the optimum add-on values to impart flame-retardancy to cotton fabric was determined and expressed by 0.80 g of potash per 100 g fabric to be an efficient addition. Thermogravimetric analysis of pure cotton, treated cotton with potash at its optimum efficiency for donation of flame-retardancy into cotton fabric was fulfilled and the thermograms were compared and commented. The effectiveness of this hydroxide was attributed to the heat dissipation by the remaining consumed material during the combustion. The results obtained are in favor of "Dust or Wall Effect Theory".

关 键 词:condensed phase retardation dust or wall effect theory FLAME-RETARDANCY gas theory POTASH THERMOGRAVIMETRY 

分 类 号:O642[理学—物理化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象